B17 Eagan MN US PV System Profile
| |
| Location: | Eagan, United States |
| Commissioning: | 10/30/2009 |
| |
| |
| |
| PV system power: | 7.000 kWp |
| Annual Production: | approx. 8,001 kWh (1,143 kWh/kWp) |
| CO2 avoided: | Approx. 4.8 tons per annum |
| |
| |
| |
| Modules: | Sunpower SPR-215-WHT |
| Inverter: | Sunny Boy 6000US |
| |
| |
|  |
Description:
Home Information
- Built in 1989
- 278 m^2 finished floor area, 2 story with finished basement, 5 bedroom
- Electricity is only fuel (atypical for area)
Energy Conservation
- Mostly Energy Star appliances
- Induction cooktop
- Flourescent & LED lighting
- Tripple glaze, krypton filled windows
- R-60 ceiling insulation
- Electricity consumption 4600 kW.h/a
HVAC
- Upgraded 2006
- Hydron Module Ground Source Heat Pump (4 ton / 14 kW capacity)
- Marathon storage water heater with desuperheater
- Steffes Electric Thermal Storage heater for backup heat during load control
- Electricity consumption 7400 kW.h/a
- Design and installation by Heating and Plumbing Consultants, Webster MN
PV
- 24 Sunpower SPR-215-WHT panels in 3 strings for 5.16 kW STC rating
- 8 Sunpower SPR-230-WHT added in 4th string on 2012-03-29 for 1.84 kW STC rating, total 7.0 kW
- SMA SB6000US 6.0 kW inverter
- Roof azimuth 225º, tilt 34º (tilt is optimal for this azimuth)
- Expected production 6200 kW.h/a until 2012-03-29. 8400 kW.h/a thereafter
- Design and Engineering by Energy Concepts, Hudson WI
- Original installation by Steiner Plumbing and Electrical, River Falls WI
- Additional installation by Summit Eco, St. Paul MN
Electric Vehicle
- Added Tesla Model S 60 on 2013-06-21
- Electricity consumption 4200 kW.h/a
- Range 240 km (winter) to 320 km (summer) per charge.
- Added Tesla Model 3 LR AWD on 2018-08-23
- Electricity consumption 4300 kW.h/a
- Range 380 km (winter) to 560 km (summer) per charge.
|